ru|en

MTU Gas Engine Power Plants

Filter
9 from 9
Name
Power
Main
Backup
Engine
Manufacturer
Gas-pistons unit 1013 kW MTU
Gas-pistons unit 1013 kW MTU
Power:
Main - 1013 kW / 1266 kWA
Engine:
8V4000L64FNER
Manufacturer:
MTU
Part number
1511013
Main power, kW
1013
Main power, kWA
1266
1013 kW
1266 kWA
8V4000L64FNER
MTU
Gas-pistons unit 1165 kW MTU
Gas-pistons unit 1165 kW MTU
Power:
Main - 1165 kW / 1456 kWA
Engine:
12V4000L32FN
Manufacturer:
MTU
Part number
1511165
Main power, kW
1165
Main power, kWA
1456
1165 kW
1456 kWA
12V4000L32FN
MTU
Gas-pistons unit 1286 kW MTU
Gas-pistons unit 1286 kW MTU
Power:
Main - 1286 kW / 1607 kWA
Engine:
12V4000L33FN
Manufacturer:
MTU
Part number
1511286
Main power, kW
1286
Main power, kWA
1607
1286 kW
1607 kWA
12V4000L33FN
MTU
Gas-pistons unit 1518 kW MTU
Gas-pistons unit 1518 kW MTU
Power:
Main - 1518 kW / 1898 kWA
Engine:
12V4000L64FN
Manufacturer:
MTU
Part number
1511518
Main power, kW
1518
Main power, kWA
1898
1518 kW
1898 kWA
12V4000L64FN
MTU
Gas-pistons unit 1557 kW MTU
Gas-pistons unit 1557 kW MTU
Power:
Main - 1557 kW / 1948 kWA
Engine:
16V4000L32FNER
Manufacturer:
MTU
Part number
1511557
Main power, kW
1557
Main power, kWA
1948
1557 kW
1948 kWA
16V4000L32FNER
MTU
Gas-pistons unit 1712 kW MTU
Gas-pistons unit 1712 kW MTU
Power:
Main - 1712 kW / 2140 kWA
Engine:
16V4000L33FN
Manufacturer:
MTU
Part number
1511712
Main power, kW
1712
Main power, kWA
2140
1712 kW
2140 kWA
16V4000L33FN
MTU
Gas-pistons unit 1948 kW MTU
Gas-pistons unit 1948 kW MTU
Power:
Main - 1948 kW / 2435 kWA
Engine:
20V4000L32ER
Manufacturer:
MTU
Part number
1511948
Main power, kW
1948
Main power, kWA
2435
1948 kW
2435 kWA
20V4000L32ER
MTU
Gas-pistons unit 2145 kW MTU
Gas-pistons unit 2145 kW MTU
Power:
Main - 2145 kW / 2681 kWA
Engine:
20V4000L33FN
Manufacturer:
MTU
Part number
1512145
Main power, kW
2145
Main power, kWA
2681
2145 kW
2681 kWA
20V4000L33FN
MTU
Gas-pistons unit 2535 kW MTU
Gas-pistons unit 2535 kW MTU
Power:
Main - 2535 kW / 3168 kWA
Engine:
20V4000L64FNER
Manufacturer:
MTU
Part number
1512535
Main power, kW
2535
Main power, kWA
3168
2535 kW
3168 kWA
20V4000L64FNER
MTU

When designing autonomous power supply systems for large facilities, operational predictability is a key factor. MTU gas power plants are used in projects where long-term continuous generation, high load stability, and strict requirements for engine service life are critical.

These solutions are in demand at industrial enterprises, mining energy clusters, oil refining facilities, and as part of energy centers for municipal and processing infrastructure.

We select MTU equipment based on the actual load profile and operating conditions — not only on nameplate specifications.

MTU engineering approach: practical benefits

MTU power plants are built on an industrial gas engine platform designed for 24/7 operation.

Key practical advantages:

  • Stable fuel efficiency — specific gas consumption starts from approx. 0.25 m³/kWh, reducing electricity generation costs.
  • Extended engine lifetime — gas engine service life reaches up to 60,000 operating hours with proper maintenance.
  • Environmental compliance — meets Euro 5 emission standards and can be integrated into projects with strict environmental regulations.
  • Cogeneration capability — simultaneous production of electricity and up to 2,200 kW of thermal energy for process heat or heating.

Configurations and installation formats

MTU gas power plants are available in a power range from 300 to 2000 kW and can be supplied in several configurations:

  • open units for installation in engine rooms;
  • containerized power plants for rapid on-site deployment;
  • modular systems for scalable energy centers.

Each unit is equipped with automatic control systems, protection, and remote monitoring functionality.

MTU vs alternative brands: when the choice is justified

During the equipment selection phase, customers often compare MTU with other manufacturers:

  • Yuchai — cost-effective solutions for budget-focused projects;
  • Jenbacher — optimized for biogas applications;
  • Jichai — commonly used in mining projects with a focus on capital cost;
  • Baudouin — balanced in terms of price and performance.

MTU is chosen when long service life, operational stability, and minimal downtime risks are the top priorities.

Supply, commissioning, and support

We provide complete project execution: equipment supply, installation, and commissioning of MTU gas power plants across Russia. Each project includes full technical documentation and professional commissioning.

Service support covers scheduled maintenance, diagnostics, and supply of original spare parts, ensuring stable generation parameters throughout the entire service life.

MTU gas power plants form a reliable foundation for autonomous power supply at facilities with high and continuous loads. Contact us to receive a technical selection and customized calculation for your project.

Читать далее
We’ll find a solution for you
Fill in the feedback form and we will contact you back
Loading
0%

News